Forged Steel Water-tube Marine Boilers ...Babcock & Wilcox, 1914 - 220 pages |
From inside the book
Results 1-5 of 20
Page 7
... SAN FRANCISCO : 99 First Street PITTSBURGH : Farmers Deposit Bank Building NEW ORLEANS : 533 Baronne Street DENVER : 435 Seventeenth Street SALT LAKE CITY : 705-6 Kearns Building PORTLAND , OREGON : 509 Spalding Building TUCSON ...
... SAN FRANCISCO : 99 First Street PITTSBURGH : Farmers Deposit Bank Building NEW ORLEANS : 533 Baronne Street DENVER : 435 Seventeenth Street SALT LAKE CITY : 705-6 Kearns Building PORTLAND , OREGON : 509 Spalding Building TUCSON ...
Page 82
... SAN FRANCISCO , CAL . BABCOCK & WILCOX BOILERS , 900 INDICATED HORSE - POWER PROPERTIES OF SATURATED STEAM BELOW ATMOSPHERIC PRESSURE Vacuum in inches. 82.
... SAN FRANCISCO , CAL . BABCOCK & WILCOX BOILERS , 900 INDICATED HORSE - POWER PROPERTIES OF SATURATED STEAM BELOW ATMOSPHERIC PRESSURE Vacuum in inches. 82.
Page 115
... San Francisco Bay under my observation . The boiler on each of these boats has about 2770 square feet of heating surface and is called upon to evaporate from 12,000 to 14,000 pounds of steam per hour . During the last eight years , the ...
... San Francisco Bay under my observation . The boiler on each of these boats has about 2770 square feet of heating surface and is called upon to evaporate from 12,000 to 14,000 pounds of steam per hour . During the last eight years , the ...
Page 117
... San Francisco , the Boston Fire Department installed our boilers in a new fire- boat and to replace an old shell boiler in another . An order for four boilers was placed with us this year by a user who has had nearly twenty years ...
... San Francisco , the Boston Fire Department installed our boilers in a new fire- boat and to replace an old shell boiler in another . An order for four boilers was placed with us this year by a user who has had nearly twenty years ...
Page 132
... SAN FRANCISCO , CAL . BABCOCK & WILCOX BOILERS , 850 INDICATED HORSE - POWER TESTS OF BABCOCK & WILCOX MARINE BOILERS Τ HE object 132.
... SAN FRANCISCO , CAL . BABCOCK & WILCOX BOILERS , 850 INDICATED HORSE - POWER TESTS OF BABCOCK & WILCOX MARINE BOILERS Τ HE object 132.
Other editions - View all
Common terms and phrases
air heater amount average BABCOCK & WILCOX Bituminous coal blower Brazilian Navy British Navy Battleship British thermal units burner burning calorimeter carbon cent Coal per hour condensed corrosion cylinders degrees Fahrenheit diameter Dredge dry coal dry steam Duluth Equivalent evaporation feed pump feed water Ferryboat Fireboat firing foot of grate foot of heating fuel furnace grate per hour grate surface heat value heating surface INDICATED HORSE-POWER installed intermediate-pressure June latent heat Lignite main engine moisture Navy Cruiser oxygen Pennsylvania Railroad Company percentage pound of combustible pound of water pounds of coal pounds pressure pressure on steam quality of steam rate of combustion Rive-de-Gier San Francisco smoke pipe square feet square foot steam gauge steam jet Steam pressure STEAMER Steamship superheated superheaters tank temperature tests thermometer total heat tubes United States Navy up-take valve vessels Water evaporated water-tube boilers weight WILCOX BOILERS WILCOX MARINE BOILER
Popular passages
Page 66 - The steam gunboat had a single scoop of modern type with a divergent nozzle based on information given in a paper read before the Society of Naval Architects and Marine Engineers of America by EF Hewins and JR Reilly.
Page 12 - The necessary supply of water is to be injected, by means of a forcing pump, into the cap at one end ; and through a tube inserted into the cap at the other end, the steam is to be conveyed to the cylinder of the steam engine. The whole is then to be encircled in brick work or masonry in the usual manner, placed either horizontally or perpendicularly, at option.
Page 127 - If it should be acid, neutralize by adding sodium carbonate. Slight alkalinity does not interfere with the reaction, but should the sample be very alkaline, it may be neutralized with nitric acid. Should it happen that the color does not change within the limits of the graduations, the sample may be tested by diluting with distilled water. For example, add three parts of distilled water to one part of the sample. If then, on testing the mixture, the color changes at 200, the number of grains per...
Page 85 - The accompanying table shows the number of British thermal units that will be absorbed by one pound of water, when heated from 32 degrees to various temperatures below 212 degrees. WATER BETWEEN 32 AND 212 DEGREES FAHRENHEIT There are four notable temperatures for pure water, viz. : 1. Freezing point at sea level, 32° F. . . . Weight per cu. ft. ,62.418 lb.; per cu. in., .03612 Ib. 2. Point of maximum density, 39.1° F.
Page 95 - This, again, involves an assumption which is open to some doubt, which is that steam, when in a quiescent state, drops all its moisture and becomes dry. No other practical method, however, has been proposed, and this is, therefore, the only method used at the present time. Some engineers, however, refuse to make any calibration, but, instead, make an assumed allowance for error. To make the calibration, close the boiler stop valve, which must be on the steam pipe beyond the calorimeter connection....
Page 67 - ... annular channel of the nozzle and put it in communication with the central chamber. The effect is that, when the burner is assembled with the washer in place, oil is delivered through the ducts tangentially to the central chamber where it rapidly revolves and almost immediately is discharged through the orifice in the tip.
Page 191 - L in which x = percentage of moisture; T = calibration reading of lower thermometer ; / = test reading of lower thermometer ; L = latent heat of steam at boiler pressure. The method of taking a sample of steam from the main is of the greatest importance, and more erroneous results are due to improper connections than to any other cause.
Page 12 - These experiments were carried no higher than 280°, at which temperature the elasticity of steam was found equal to about four times the pressure of the atmosphere. By experiments which have lately been made by myself, the elasticity of steam at the temperature of boiling oil, which has been estimated at about 600°, was found to equal forty times the pressure of the atmosphere.
Page 21 - Each section is made up of a series of straight tubes expanded at their ends into sinuous steel boxes known as " headers." The tubes are thus staggered. Extending across the front of the boiler, and connected to the upper ends of the front headers by short tubes, is a horizontal steam and water drum of ample dimensions. As the upper ends of the rear headers are also connected to this drum by horizontal tubes, each section is provided with an inlet and outlet for steam and water.
Page 85 - Sea water (average) has a specific gravity of 1.028, boils at 213.2 degrees F., and weighs 64 pounds per cubic foot at 62 degrees Fahrenheit.