Ordinances No. 46388: The Building Code of the City of Cleveland, Ohio

Front Cover
1904 - 266 pages
 

Contents

Other editions - View all

Common terms and phrases

Popular passages

Page 222 - ... shall always remain easy of access and ready for use in each of said buildings, to give notice to the inmates in case of fire; and every keeper of such hotel...
Page 143 - ... feet from the rear line of the house. The depth of said yard, measured from the extreme rear wall of the house to the rear line of the lot, shall...
Page 77 - Stiffeners shall be provided over supports and under concentrated loads ; they shall be of sufficient strength, as a column, to carry the loads, and shall be connected with a sufficient number of rivets to transmit the stresses into the web plate. Stiffeners shall fit so as to support the flanges of the girders. If the unsupported depth of the web plate exceeds sixty times its thickness, stiffeners shall be used at intervals not exceeding one hundred and twenty times the thickness of the web.
Page 34 - A tenement house within the meaning of this act shall be taken to mean and include every house, building, or portion thereof, which is rented, leased, let or hired out to be occupied or is occupied as the home or residence of three families or more living independently of each other, and doing their cooking upon the premises, or by more than two families upon a floor, so liv"Ing and cooking, but having a common right in the halls, stairways, yards, water-closets or privies, or some of them.
Page 170 - ... incombustible materials, so as to prevent the passage of air or the spread of fire from one floor to another or from room to room.
Page 73 - The strain in any fibre is directly proportionate to the distance of that fibre from the neutral axis. (c) The modulus of elasticity of the concrete remains constant within the limits of the working stresses fixed in these Regulations.
Page 184 - All aisles and passageways in said buildings shall be kept free from camp stools, chairs, sofas and other obstructions, and no person shall be allowed to stand in or occupy any of said aisles or passageways during any performance, service, exhibition, lecture, concert, ball or any public assemblage.
Page 185 - Distinct and separate places of exit and entrance shall be provided for each gallery above the first. A common place of exit and entrance may serve for the main floor of the auditorium and the first gallery, provided Its capacity be equal to the aggregate capacity of the outlets from the main floor and the said gallery. No passage leading to any stairway communicating with any entrance or exit shall be less than four feet in width in any part thereof.
Page 41 - When a doubt arises as to the safe sustaining power of the earth upon which a building is to be erected the...
Page 184 - ... to five running feet. Aisles having seats on one side only, shall be not less than two feet wide at their beginning and increased...