" Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion of each and every floor depending upon it for support, in addition to the weight required as before stated to be supported safely upon... "
Compiled Ordinances of the City of St. Paul, Minnesota - Page 683
by Saint Paul (Minn.). - 1908 - 1245 pages
Full view - About this book

Laws of the State of New York, Volume 1

New York (State) - 1894 - 1188 pages
...of materials composing the same. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion...as before stated, to be supported safely upon said portions of said floor. The dimensions of each piece, or combination of materials required, shall be...
Full view - About this book

Geer's Hartford City Directory, Volume 59

1896 - 788 pages
...other vertical support shall be of sufficient strength to bear safely the weight of material and load of the portion of each and every floor depending upon it for support. No cast-iron column shall be less than three-fourth of an inch in thickness. Columns where placed over...
Full view - About this book

The Planning and Construction of High Office-buildings

William Harvey Birkmire - 1898 - 376 pages
...BUILDING LAW. — Section 483. Every column, post, or other vertical support shall be of sufficient strength to bear safely the weight of the portion...depending upon it for support, in addition to the weight which the floors support. The dimensions of each piece or combination of materials required shall be...
Full view - About this book

The Sanitary Code: 1899 ...

1899 - 462 pages
...every column, post or other vertical support shall be of sufficient strength to bear safely the weights of the portion of each and every floor depending upon...for support, in addition to the weight required as aobve to be supported safely upon said portions of said floors. 2368. No building already erected or...
Full view - About this book

The Sanitary code [Louisiana] 1899 ...

Louisiana - 1899 - 460 pages
...every column, post or other vertical support shall be of sufficient strength to bear safely the weights of the portion of each and every floor depending upon...for support, in addition to the weight required as aohve to be supported safely upon said portions of said floors. 2368. No building already erected or...
Full view - About this book

The Building Code of the City of New York

New York (N.Y.) - 1901 - 186 pages
...pounds upon [every superficial foot. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion...columns in dwellings, office buildings, stores, stables and public buildings when over five stories in height, a reduction of the live loads shall be permissible...
Full view - About this book

Architectural Engineering: With Special Reference to High Building ...

Joseph Kendall Freitag - 1901 - 456 pages
...full floor-loads on girders, but provides for a reduction in the live loads on columns as follows: " For the purpose of determining the carrying capacity...columns in dwellings, office buildings, stores, stables, and public buildings when over five' stories in height, a reduction of the live loads shall be permissible...
Full view - About this book

Building-law of the Town of Brookline, Adopted March 31, 1903, Approved by ...

Brookline (Mass.). - 1903 - 142 pages
...pounds upon every superficial foot. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion of each and every floor depending on it for support, in addition to the weight required as before stated to be supported safely upon...
Full view - About this book

Structural Designers' Handbook: Giving Diagrams and Tables for the Design of ...

William Fry Scott - 1904 - 192 pages
...pitch more than 20° 30 " (load on a horizontal plane.) Sidewalks between the curb and area lines 300 " "For the purpose of determining the carrying capacity...columns in dwellings, office buildings, stores, stables and public buildings when over five stories in height, a reduction of the live loads shall be permissible...
Full view - About this book

Structural Designers' Handbook: Giving Diagrams and Tables for the Design of ...

William Fry Scott - 1904 - 176 pages
...pitch more than 20° 30 " (load on a horizontal plane.) Sidewalks between the curb and area lines 300 " "For the purpose of determining the carrying capacity...columns in dwellings, office buildings, stores, stables and public buildings when over five stories in height, a reduction of the live loads shall be permissible...