| National Board of Fire Underwriters - 1909 - 280 pages
...superficial foot. Vertical Supports. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion...as before stated to be supported safely upon said portions of said floors. Reduction in Live Loads on Columns. For the purpose of determining the carrying... | |
| 1909 - 354 pages
...every column, post or other vertical support shall be of sufficient strength to bear safely the weights of the portion of each and every floor depending upon...for support, in addition to the weight required as above to be supported safely upon said portions of said floors. 680. No building already erected or... | |
| East Orange (N.J.). - 1910 - 80 pages
...measured on a horizontal plane. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion...as before stated, to be supported safely upon said portions of said floors. Section 44. The dimensions of each piece or combination of materials required... | |
| Portland (Me.) - 1911 - 1220 pages
...measured on a horizontal plane. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion...purpose of determining the carrying capacity of columns of dwellings, office buildings, stores, stables and public buildings when over five stories in height,... | |
| Dallas (Tex.). - 1914 - 266 pages
...a horizontal plane. The vertical supports shall be of sufficient strength to bear safely the weight of each and every floor depending upon it for support,...supported safely upon said portion of said floors. STRUCTURAL LOADS. SEC. 31. In all cases provisions shall be made for carrying the full superimposed... | |
| Little Rock (Ark.). - 1915 - 770 pages
...PROPORTIONMENT OF LOADS. Sec. 114. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion of each and every floor depending upon it. In calculating the necessary strength of columns in office, store, stable, public and similar buildings,... | |
| Urbana (Ill.) - 1916 - 442 pages
...weight composing the same. Vertical supports shall be of sufficient strength to bear safely the weight of each and every floor depending upon it for support...weight required as before stated, to be supported upon said portion of said floor. The weight placed on any floor of any building, shall be safely distributed... | |
| Haverhill (Mass.) - 1919 - 530 pages
...or counter sinkages. SECT. 67. Every column, post or other vertical support shall be of sufficient strength to bear safely the weight of the portion...it for support, in addition to the weight required to be supported safely upon the floors which the column carries as contained in the section of this... | |
| |